Model : LS590-*****- ** | |||||||||||
****G | 0075G | 0110G | 0150G | 0185G | 0220G | 0300G | 0370G | 0450G | 0550G | 0750G | |
Rated power (kw) | 7.5 | 11 | 15 | 18.5 | 22 | 30 | 37 | 45 | 55 | 75 | |
Rated current (A) | 17 | 25 | 32 | 37 | 45 | 60 | 75 | 91 | 112 | 150 | |
Maximum Holding Current (A) Continuous 60s |
25.5 | 37.5 | 48 | 55.5 | 67.5 | 90 | 112.5 | 136.5 | 168 | 225 | |
Power Supply Input |
Rated Voltage and Frequency |
3-phase 350, 380, 400, 420, 50/60Hz | |||||||||
Allowed Voltage Range |
±15% | ||||||||||
Allowed Frequency Range |
±5% | ||||||||||
Brake Resistance |
kW | Build in | |||||||||
Ω | |||||||||||
Resolver Signal Cable (according to model) |
ZF80-**** stands for cable length, unit: cm. For example, ZF80-400 means that the cable length is 4 meters. |
||||||||||
Pressure Sensor(necessary) | Could choose a variety of pressure sensors, the measuring range selection corresponding to parameters A3-03 (the measuring range of pressure sensor), recommended Danfoss 060G3557. |
||||||||||
Breaker | 50 | 50 | 60 | 75 | 100 | 100 | 150 | 150 | 200 | 300 | |
Contactor | 30 | 30 | 50 | 50 | 50 | 80 | 100 | 100 | 160 | 250 | |
Basic Function | Max frequency Maximum Frequency |
300Hz | |||||||||
Carrier Frequency | 1KHz~8KHz; the carrier frequency could automatically adjusted based on the load features. |
||||||||||
Input Frequency Resolution |
Digital setting: 0.01Hz; Analog setting: maximum frequency × 0.1% |
||||||||||
Control Mode | Closed-loop vector control (VC); V/F control | ||||||||||
Starting Torque | 0Hz/180% (VC) | ||||||||||
Speed Range | 1:1000 (VC) | ||||||||||
Steady Speed Precision |
±0.02% (VC) | ||||||||||
Torque Control Precision |
±5% (VC) | ||||||||||
Overload Capacity | 150% rated output current: 60s 180% rated output current: 3s |
||||||||||
Auto Voltage Regulation (AVR) |
It can keep constant output voltage automatically when the network voltage changes. | ||||||||||
Protection Function | Motor short-circuit detection at power-on, input/output phase loss protection, over current protection, over voltage protection, under voltage protection, overheat protection and overload protection |
||||||||||
Environment | Installation Location | Indoor, free from direct sunlight, dust, corrosive gas, combustible gas,oil smoke, vapour, drip or salt. | |||||||||
Altitude | lower than 1000m (decrease if higher than 1000m) | ||||||||||
Ambient Temperature |
-10℃~+40 ℃ (decrease if the ambient temperature is between 40℃ and 50℃) | ||||||||||
Humidity | less than 95%RH, without condensing | ||||||||||
Vibration Vibration |
less than 5.9 m/s2 (0.6 g) | ||||||||||
Storage Temperature | -20℃~+60℃ | ||||||||||
IP Level | IP20 |